✔ Innovative, Tactical Design – Developed for active-duty military and law enforcement professionals, offering a shooter-friendly, low-profile fit.
✔ NATO-Standard Compatibility – Utilizes widely available 40mm filter cartridges for maximum versatility.
✔ Standalone or Integrated Use – Features a custom mesh head harness for independent wear and an optional FIDLOCK buckle system for seamless helmet integration with ARC rail systems.
✔ Helmet & Eye Protection Compatibility – Works with leading riot control helmets, including MSA Gallet and Schuberth models, and accommodates various protective goggles, shields, and face masks.
✔ Ultralight & Durable Construction – Weighs just over 4 oz (without filter) and is made from high-quality, sanitary silicone rubber for long-term durability.
✔ One-Size-Fits-All Design – Anatomically engineered with an advanced harness system for a secure and comfortable fit on all users.
✔ Enhanced Communication Capabilities – Compatible with the MIRA Gas Mask Microphone (sold separately) for seamless integration with communication systems.
✔ Optimized for Compact Filters – Works with three compact gas mask filters: P-CAN Compact, Particlemax P3 Compact, and NBC-17 SOF.
✔ Efficient Breathing System – Dual exhalation valves reduce resistance for improved comfort during extended wear.
✔ Easy Maintenance – Can be cleaned with common disinfectants for safe, repeated use.
✔ Protective Storage – Includes a hardened travel case for secure transport and storage.
✔ Reliable Warranty – Backed by MIRA Safety’s 1-year manufacturer warranty.
✔ Versatile Protection for Tactical Operations - Modern tactical professionals require flexible protective solutions, and the TAPR Respirator Mask delivers. Whether deployed in combat zones, riot control situations, emergency response operations, or hazardous environments, this modular respirator provides unmatched protection without sacrificing agility or communication.
Materials & Construction:
- Made from high-quality sanitary silicone rubber for durability and comfort
- Custom mesh head harness for standalone use
- Dual exhalation valves for easy breathing during prolonged use
- Optional FIDLOCK buckle system for rapid deployment with helmets
Weight & Dimensions:
- Weight: 120 g (just over 4 oz. without filter)
- Size: Universal fit
- Compact design for ease of carrying and storage
Filter Compatibility:
- Uses widely available NATO-standard 40-mm filter cartridges (EN 148-1, NATO STANAG 4155, 40×1/7” threading)
- Compatible filters include:
- P-CAN Compact
- Particlemax P3 Compact
- NBC-17 SOF
- DOTpro 320
Protection Level:
- Protects against a range of airborne threats, including:
- Organic gases and vapors (boiling point > 65°C)
- Inorganic gases and vapors (chlorine, H2S, HCN, etc.)
- Acid gases (SO2, HCl, etc.)
- Ammonia and organic derivatives
- Nitrogen oxides (NO, NO2, Nox)
- Mercury vapors
- Particulates (>99.99% efficiency)
- Not designed for prolonged exposure to CBRN threats, blister agents, or toxic industrial chemicals
Certifications & Compliance:
- EN-140 certified half-face respirator mask
- Designed for compliance with tactical, military, and law enforcement safety standards
Additional Features:
- Anatomical design provides a one-size-fits-all fit
- Compatible with riot control helmet systems such as MSA Gallet and Schuberth helmets
- Can be used with various protective goggles, shields, and face masks
- Compatible with MIRA Safety’s proprietary Gas Mask Microphone (sold separately)
- Low-profile exhalation cap included
- Comes with a hardened travel case and nylon pouch for secure storage
- Easy maintenance—can be cleaned with common disinfectants for regular use
- 1-year manufacturer warranty from MIRA Safety
Applications:
The TAPR is designed to provide tactical effectiveness while maintaining optimal protection in various high-risk environments, including:
- Tactical Operations – Designed for military professionals in dynamic combat scenarios.
- Riot Control & SWAT Use – Provides reliable protection for law enforcement professionals.
- Police & Emergency Patrol – Suitable for security and emergency response teams.
- Readiness Planning – Ideal for preppers and emergency preparedness.
- Particulate Protection and More – Guards against airborne threats.
- Shooting Range Protection – Ensures respiratory safety in high-particulate environments.
The Tactical Air-Purifying Respirator (TAPR®) is a universal-fit half-face respirator mask designed to provide adaptable protection for various tactical operations. Below, you will find a detailed breakdown of the sizing and fitting process to ensure optimal performance.
Initial Fitting:
- Place the TAPR® on your face and pull the harness over your head.
- Adjust straps for a snug yet comfortable fit.
- Ensure the facepiece seals properly against your skin.
Seal Check
- Cover the filter port with your palm and inhale gently.
- A proper fit causes the mask to collapse slightly without air leaks.
- If leaks occur, readjust the straps and retest.
- Ensure no excessive pressure points.
- Adjust the harness for even weight distribution and stability.
Warranty:
The Tactical Air-Purifying Respirator (TAPR®) comes with MIRA Safety’s 1-year manufacturer warranty. This warranty covers any defects in materials and workmanship under normal use.
Key Warranty Conditions:
- The warranty applies only to the original purchaser and is non-transferable.
- Coverage includes manufacturing defects but does not cover damage due to misuse, improper storage, modifications, or exposure to extreme conditions.
- Customers must retain proof of purchase to claim warranty services.
- Warranty claims should be processed through MIRA Safety’s customer support, and the company reserves the right to repair, replace, or refund the product at its discretion.
- Filters and consumable items are not covered under this warranty, as their lifespan depends on environmental exposure and usage.
Shelf Life:
The TAPR respirator mask itself, made from high-quality sanitary silicone rubber, does not have a strict expiration date but requires proper storage to maintain its integrity.
Storage Guidelines:
To maintain the longevity and effectiveness of the TAPR respirator It must be stored in a dark, cool, and dust-free location with regular ventilation. Ensure storage:
- Temperature: 5°C to 25°C
- Relative Humidity: Up to 65%
- Avoid exposure to radiant heat or direct sunlight.
- Keep away from fuels, solvents, lubricants, and chemicals.
- Avoid electrical machines or appliances that produce sparks (ozone risk).
- Prevent deformation of rubber parts during storage.
Important Notice:
The TAPR Respirator Mask is not intended for CBRN protection and should not be used for prolonged exposure to unknown toxic environments, blister agents, or industrial chemicals.